Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Arq. bras. oftalmol ; 72(4): 526-532, July-Aug. 2009. graf, tab
Article in English | LILACS | ID: lil-528020

ABSTRACT

PURPOSE: To compare the visual outcome, contrast sensitivity and wavefront analysis of patients that underwent cataract surgery and implantation of AcrySof SN60D3 multifocal intraocular lens with those who received the AcrySof SN60AT monofocal IOL. METHODS: This was a prospective clinical trial of forty eyes that received the multifocal IOL and thirty-two eyes that received the monofocal IOL after phacoemulsification. RESULTS: Values for total and spherical aberrations in the multifocal group were statistically lower than in the monofocal group. In the monofocal group, 75 percent achieved uncorrected intermediate visual acuities between Jaeger 1 and 6. In the multifocal group, 75 percent of the eyes achieved more than Jaeger 6. At least 87.5 percent of the multifocal group and 6.3 percent of the monofocal group achieved monocular uncorrected near acuity of 20/30 (J2, N5) or better. And 90.0 percent of the eyes in the multifocal group and 37.5 percent in the monofocal group achieved an uncorrected near acuity of 20/40 (J3, N6) or better. The mean spherical error was 0.11 D in the multifocal group and -0.18 D in the monofocal group (p=0.0379). The SN60D3 group compared to SN60AT group had low contrast sensitivity (log units) with statistically significant differences in 6.0 cpd in photopic conditions (p=0.014) and the SN60D3 group compared to SN60AT group had higher contrast sensitivity (log units) under mesopic conditions (p=0.044). CONCLUSION: The multifocal IOLs induced less spherical aberration than monofocal IOLs and predictably good uncorrected distance and uncorrected near acuities. However, contrast sensitivity was lower in the multifocal group.


OBJETIVO: Comparar a performance visual, sensibilidade ao contraste e de wavefront com OPD-Scan em pacientes submetidos a cirurgia de facoemulsificação com implante de lente intraocular AcrySof SN60D3 multifocal e AcrySof SA60AT monofocal. MÉTODOS: Quarenta olhos com a lente intraocular multifocal e trinta e dois olhos com a lente intraocular monofocal. A avaliação oftalmológica contou com medida da acuidade visual para longe, intermediária e curta distância, sem correção e com a melhor correção óptica, teste de sensibilidade ao contraste e análise de frente de onda por meio do aberrômetro OPD-Scan. RESULTADOS: As aberração total e aberração esférica no grupo multifocal foi estatisticamente inferior comparada com o grupo monofocal. No grupo monofocal 75 por cento apresentaram acuidade visual monocular intermediária sem correção entre Jaeger 1 e 6, no grupo multifocal 75 por cento apresentaram mais que Jaeger 6. Aproximadamente 87,5 por cento do grupo multifocal e 6,3 por cento do grupo monofocal apresentaram acuidade visual monocular sem correção para perto de 20/30 (J2, N5), ou melhor, e 90,0 por cento dos olhos do grupo multifocal e 37,5 por cento do grupo monofocal apresentaram acuidade visual monocular sem correção para perto de 20/40 (J3, N6) ou melhor. A média de erro esférico foi de 0,11 D no grupo multifocal e -0,18 D no grupo monofocal (p=0,0379). O grupo monofocal apresentou superioridade estatística na sensibilidade ao contraste em condições fotópicas (p=0,014) e mesópicas (p=0,0044) a 6 cpg quando comparada ao grupo multifocal. CONCLUSÃO: A lente intraocular multifocal apresentou menos aberração esférica comparada à lente intraocular monofocal, da prevista multifocalidade sem correção para longe e perto. Entretanto, o grupo multifocal apresentou baixa sensibilidade ao contraste.


Subject(s)
Aged , Humans , Middle Aged , Contrast Sensitivity , Lens Implantation, Intraocular , Phacoemulsification/methods , Visual Acuity , Prospective Studies , Treatment Outcome
2.
Rev. bras. oftalmol ; 67(3): 119-124, maio-jun. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-487526

ABSTRACT

OBJETIVO: Comparar a análise da frente de onda e a sensibilidade de contraste pós-operatórias em pacientes submetidos à facoemulsificação com implante de lentes intra-oculares esféricas num olho e asféricas no olho contralateral. MÉTODOS: Este estudo prospectivo comparativo, randomizado, duplo-cego, incluiu 32 olhos de 16 pacientes. Uma avaliação oftalmológica completa foi realizada durante as visitas antes e depois da cirurgia (no primeiro, terceiro, sétimo, e nonagésimo dias pós-cirúrgicos), que incluiu acuidade visual, teste de sensibilidade ao contraste, aberrometria. Todos exames (menos aberrometr=ia) foram feitos monocularmente com pupilas não dilatadas. Os pacientes foram submetidos a facectomia ultra-sônica convencional com implante de uma lente asférica SN60WF num olho e esférica SN60ATno outro. RESULTADOS: A acuidade visual média com a melhor correção foi -0,146 LogMAR no grupo da lente intra-ocular esférica, e -0.165 logMAR no grupo da lente intra-ocular asférica sob condições fotópicas, -0,003 LogMAR sob condições mesópicas. A sensibilidade ao contraste foi semelhante em ambos os grupos tanto em condições fotópicas e mesópicas. Em relação às aberrações ópticas ocorreu uma diferença significativa nas aberrações totais (1,09 ± 0,56 no grupo asférico e 1,52 ± 1,19 no grupo esférico) e no componente esférico das aberrações de alta ordem(0,422 ± 0,202 no grupo asférico e 0,124 ± 0,087 no grupo esférico). CONCLUSÃO: As duas lentes intra-oculares promoveram uma excelente visão em situações de alto contraste, e os olhos implantados com a lente asférica tiveram menos aberrações totais e esféricas que aqueles implantados com a lente esférica.


PURPOSE: Compare the wavefront and contrast sensitivity of bilateral pseudophakic patients with aspheric in one eye and spheric intraocular lenses in the other. METHODS: This prospective, comparative, randomized study, double masked, included 32 eyes of 16 patients. A complete ophthalmic evaluation was done before, and after surgery at days 1,3, 7 and 90, and included best corrected visual acuity, the contrast sensitivity, under photopic and mesopic conditions, and aberrometry. Almost all exams were done monocularly with undilated pupils (aberrometry under pharmacological dilatation). The patients eyes were operated with conventional phacoemulsification, with aspheric intraocular lenses in one eye, and spherical in the other. RESULTS: The visual acuity with the best correction was -0.146 in the spheric group, and -0.165 logMAR in the aspheric group in photopic conditions, and 0.024 and -0.003 LogMAR under mesopic conditions. The contrast sensitivity under photopic and mesopic conditions was similar comparing the two groups. In regard to optical aberrations there was a significant diference between the total (1.09 ± 0.56 in the aspheric, and 1.52± 1.19 in the spherical group) and spherical component of high order aberrations (0.422± 0.202 in spheric group and 0.124 ± 0.087 in the aspheric group). CONCLUSION: Both groups reached excellent postoperative visual acuity in high contrast situations, however aspheric intraocular lenses group had lower total and spherical aberrations, comparing to the spheric intraocular lenses group.

SELECTION OF CITATIONS
SEARCH DETAIL